GPS ANTENNA | |
Model | T-GPA-014-S15 |
Receiving Frequency | 1575.42 MHz +/- 1 MHz |
Tracking code | ‘L’ Band CA code |
Geodetic System | WGS – 84 |
No. of Channels | 24 Channel / Parallel |
Type | Helical |
Axial Ratio | <4 dB |
Supply Voltage | +5V DC (Internal) |
Gain | Over 40 dB |
Noise Figure | Less than 1.5 dB |
Operating Temp | 40 °C to +85 °C |
Connector | BNC |
Dimension | 80(h)x55(d) x 82(w) mm |
Mounting | Fixed (Roof mount) |
GPS RECEIVER | |
Model | T-GPS-300-D28 |
Interface | TTL (Normal High) |
Input connector | BNC |
Output Rate | Every second |
Power Supply | 24V/48V DC
90 to 260v AC&DC Operation |
Display | 2 x 16 LCD |
Type | GPS: L1 C/A, L2C,
GLO: L1OF, L2OF,
GAL: E1B/C
BDS: B1I, B2I 32 Channel Parallel-tracking receiver |
Frequency | 1575.42 Mhz |
Sensitivity (Acquisition) | -148 dBm |
Sensitivity (Tracking) | -167 dBm |
Mount | Din Rail |
Output Connector | BNC & RJ45 |
Output | IRIG B (AM) & NTP/SNTP |
Status Indicator | Power ON, Lock |
ENVIRONMENT | |
Storage Temperature | -40 to +85 °C |
Operating Temperature | -10 to+55 °C |
Humidity | 0 – 95% RH, non-condensing |
Power Drain | 45 w max |
Power Supplies | L = 14 - 36 Vdc
M = 20 - 75 Vdc
H = 90 - 300 Vdc |
Programmable output options | IRIG-B (B00x / B22x) time code with selectable C37.118.1 and AFNOR S87-500 extensions.
DCF77 time code
1 kHz square wave
User defined pulse sequences:
−1PPS/PPM/PPD/PPPH
− Offsets and durations from 10 ms to 24 hours |
MECHANICAL SPECIFICATION | |
Dimensions | (W) 72 mm x (D) 60 mm x (H) 90 mm
|
Mounting | Din Rail |
Weight | 1.5 KG |
Programmability | |
Platform | Windows based configuration software |
INPUT *Feature Available only on Specific requests and suitable price points | |
GNSS Antenna inputs | L1Band GNSS, BNC [F] |
Ethernet Connections | RJ45 1GbE/Fast Ethernet SFP 1GbE`/Fast Ethernet *Feature Available only on Specific Requests and suitable price points |
Input | GNSS Signal [BNC] |
Antenna Input | BNC 5V GNSS Input |
Alarm Relay | 3-Pin Form-C NO/NC alarm relay* |
OUTPUT *Feature Available only on Specific requests and suitable price points | |
1PPS | TTL, 50 Ω Impedance, BNC [F] |
IRIG-B | AM [B125], BNC [F] |
Impedance | 50 Ω Sine Wave |
NETWORK TIME SERVER OPTION | |
NTP/SNTP | Stratum-1 NTP & SNTP time server |
Protocols supported | ARP, UDP, ICMP |
TEST AND STANDARDS | |
Dry Heat Test | IEC 60068-2-2 |
Cold Test | IEC 60068-2-1 |
Damp Heat (Steady State) Test | IEC 60068-2-3 |
Sinusoidal Vibration Test | IEC 60068-2-6 |
Dielectric Strength Test | IEC 60255-5-0 |
Pulse Magnetic Field Test | IEC 61000-4-9,2016 |
Radiated RF Power Disturbance | CISPR 14-1,2009 |
Voltage Fluctuation and Flicker Emission Test
| IEC 61000-3-3,2013 |
Harmonics, Inter Harmonics and Low Frequency Immunity Test | IEC 61000-4-13,2002 |
Electrostatic Discharge Immunity Test | IEC 61000-4-2,2008 |
Radiated Susceptibility Test | IEC 61000-4-3,2010 |
Electrical Fast Transient Immunity | IEC 61000-4-4,2012 |
High Energy Surge Immunity Test | IEC 61000-4-5,2014 |
Conducted RF Immunity Test | IEC 61000-4-6,2013 |
Power Frequency Magnetic Field Test | IEC 61000-4-8,2009 |
Damped Oscillatory Sinusoidal Immunity Test | IEC 61000-4-18,2011 |
Voltage Dips and Interruption Immunity Test | IEC 61000-4-11 |
*Feature Available only on Specific Requests and suitable price points
*Output ports are customizable based on the requirements
*Product development is continuous process, subject to change without prior notice | |