| GPS ANTENNA | |
| Model | T-GPA-014-S15 |
| Receiving Frequency | L1- 1575.42 MHz
L5- 1176 Mhz |
| Tracking code | ‘L’ Band CA code |
| Geodetic System | WGS – 84 |
| No. of Channels | 24 Channel / Parallel |
| Type | Helical |
| Axial Ratio | <4 dB |
| Supply Voltage | +5V DC (Internal) |
| Gain | Over 40 dB |
| Noise Figure | Less than 1.5 dB |
| Operating Temp | -40 °C to +85 °C |
| Connector | BNC |
| Dimension | 80(h)x55(d) x 82(w) mm |
| Mounting | Fixed (Roof mount)
IP67 (Ingress Protection Rating)
|
| GPS RECEIVER | |
| Model | T-GPS-300-NTPS |
| Interface | TTL (Normal High)
|
| Input connector | BNC |
| Output Rate | Every second |
| Power Supply | 90-260 V AC/DC A & B
|
| Display | 4x40 / 2x16 / 2x20 LCD |
| Type | GPS: L1 C/A, L2C,
GLO: L1OF, L2OF,
GAL: E1B/C
BDS: B1I, B2I
184 Channel Parallel-tracking
receivers |
| Frequency | L1 / L5 Band |
| Sensitivity (Acquisition) | -148 dBm |
| Sensitivity (Tracking) | -167 dBm |
| Design | 1U/2U/3U rack mount bracket
designed for 19 Inch Cabinets Fabricated Heatsinks IP40 (Ingress Protection Rating) |
| Protocol | NMEA, Sertel Format, Serial String ASCII format. |
| ENVIRONMENT | |
| Storage Temperature | 40 °C to +85 °C |
| Operating Temperature | -10 °C to +55 °C |
| Humidity | 0 – 95% RH, non-condensing |
| Power Drain | 60W *Depends on Output configuration |
| Power Supplies | 1x or 2x Power Supplies
High Voltage - AC/DC
90-370 VDC
80-260 VAC
Low Voltage - DC
24-60 VDC
*Feature Available only on Specific requests and suitable price points |
| Ingress Protection | IP40 |
| Configuration Software | |
| Platform | HTTPS/SSL Browser-based configuration |
| MECHANICAL SPECIFICATION | |
| Dimensions | 1U(H) x 485(W) x 185(D) mm (Or)
2U(H) x 485(W) x 185(D) mm (Or)
3U(H) x 485(W) x 185(D) mm *Size Depends on number of outputs |
| Mounting | 19” Rack |
| Weight | 2.5 KG |
| Oscillator Options *Feature Available only on Specific requests and suitable price points | |
| Disciplined Oscillator | TBC* |
| Rubidium | TBC* |
| VCTCXO | TBC* |
| OCXO | TBC* |
| INPUT* | |
| GNSS Antenna inputs | GNSS, BNC [F] |
| External 1PPS | TTL, BNC [F] |
| External IRIG-B | TTL/AM, BNC [F] |
| External 10Mhz | 0 to 13dBm, BNC [F] |
| Impedance | 50 Ω Sine Wave |
| External NTP | Lock to External Input, RJ45 |
| Configuration | Web server Interface and Sertel Time
Management Suite for complete
accessibility and configurability of
server.
SNMP for remote management
Keypad for local configuration
L1Band GNSS, BNC [F]
*Feature Available only on Specific Requests and suitable price points |
| Ethernet Connections | RJ45 1GbE/Fast Ethernet
SFP 1GbE`/Fast Ethernet
*Feature Available only on Specific Requests and suitable price points |
| Input | DC IRIG-B Input (BNC) |
| OUTPUT * | |
| 1PPS | TTL, 50 Ω Impedance, BNC [F] |
| IRIG-B | AM [B125], BNC [F] |
| 10 MHz | 10dBm, ±1dBM, BNC [F] |
| Impedance | 50 Ω Sine Wave |
| T1/E1/J1 Output | RJ48 T1/E1/J1 Output |
| Fiber Output | ST Fibre 62.5/125 µm, ʎ 820 nm |
| Programmable Output | TTL or Frequency Output (1.544,
2.048, 10MHz, Sine or Square) (BNC)
TTL or AM IRIG-B Output (BNC)
TTL Input/Output (BNC)
ST Fiber (62.5/125 µm) multi-mode
HV MOSFET 300V 1A (2-pin)
*Feature Available only on Specific requests and suitable price points |
| Ethernet Output | RJ45 - Time Protocols NTP, PTP |
| Ethernet Connections | RJ45 1GbE/Fast Ethernet
SFP 1GbE`/Fast Ethernet
*Feature Available only on Specific Requests and suitable price points |
| Alarm Relay | 3-Pin Form-C NO/NC alarm relay |
| NETWORK TIME SERVER OPTION | |
| IEEE 1588v2 (PTP) | P2P/E2E delay
1-Step/2-Step delay
C37.238:2011 Power Profile
C37.238:2017 Power Profile
ITU G.8265.1 Telecom Profile
ITU G.8275.1 Telecom Profile
IEEE 61850-9-3 Power Utility
Profile |
| PRP | IEC 62439-3 (2016)
Fast failover slave
Supports up to two PRP
pairs
PTP (IEEE 1588v2) Default
& Power Profiles |
| CLOCK ACCURACY TO UTC | |
| AM IRIG-B | < 100 ns |
| 1 PPS | < 100 ns |
| NTP Timestamp at Server Source | < 1 μs (At client End Depends on Network Architecture for more accuracy) |
| NTP/SNTP | Stratum 1 NTP & SNTP Time server
Multicast & Broadcast capability |
| SNMP | V1, V2C & V3 support can be
independently enabled Configurable V1, V2C community names & security
groups Fully configurable via Custom
SERTEL MIB, SNMP;
|
| Protocols supported | ARP, UDP, ICMP, DHCP, SNMP, HTTPS, IPV4 |
| TTL/Fiber: | < 100 ns |
| PTP Time Stamp | < 100 ns |
| Security | Local Authentication --
TACACS+/RADIUS/LDAP methods Encryption for NTP, SNMP using MD5/SHA algorithms. |
| Notifications | SNMP trap generation V1,
V2C & V3
SNMPv3 traps can be
authenticated
Syslog (RFC-3164 & 5424
verities) |
*Feature Available only on Specific Requests and suitable price points | |
| TEST AND STANDARDS | |
| Dry Heat Test | IEC 60068-2-2 |
| Cold Test | IEC 60068-2-1 |
| Damp Heat (Steady State) Test | IEC 60068-2-3 |
| Sinusoidal Vibration Test | IEC 60068-2-6 |
| Dielectric Strength Test | IEC 60255-5-0 |
| Pulse Magnetic Field Test | IEC 61000-4-9,2016 |
| Radiated RF Power Disturbance | CISPR 14-1,2009 |
Voltage Fluctuation and Flicker Emission Test
| IEC 61000-3-3,2013 |
Harmonics, Inter Harmonics and Low
Frequency Immunity Test | IEC 61000-4-13,2002 |
| Electrostatic Discharge Immunity Test | IEC 61000-4-2,2008 |
| Radiated Susceptibility Test | IEC 61000-4-3,2010 |
| Electrical Fast Transient Immunity | IEC 61000-4-4,2012 |
| High Energy Surge Immunity Test | IEC 61000-4-5,2014 |
| Conducted RF Immunity Test | IEC 61000-4-6,2013 |
| Power Frequency Magnetic Field Test | IEC 61000-4-8,2009 |
Damped Oscillatory Sinusoidal Immunity
Test | IEC 61000-4-18,2011
|
| Voltage Dips and Interruption Immunity Test | IEC 61000-4-11 |
*Feature Available only on Specific requests and suitable price points
*Output ports are customizable based on the requirements