| GNSS ANTENNA | |
| Model | T-GPA-014-S15 |
| Receiving Frequency | 1575.42 MHz +/- 1 MHz |
| Tracking code | ‘L’ Band CA code |
| Geodetic System | WGS – 84 |
| No. of Channels | 24 Channel / Parallel |
| Type | Helical |
| Axial Ratio | <4 dB |
| Supply Voltage | +5V DC (Internal) |
| Gain | Over 40 dB |
| Noise Figure | Less than 1.5 dB |
| Operating Temp | -40 °C to +85 °C |
| Connector | BNC |
| Dimension | 80(h)x55(d) x 82(w) mm |
| Mounting | Fixed (Roof mount) |
| GNSS RECEIVER | |
| Model | T-GPS-300-PTPGM |
| Interface | TTL (Normal High) |
| Input connector | BNC |
| Output Rate | Every Second |
| Power Supply | 90-260 V AC/DC A & B |
| Display | 2 x16 / 2x20 LCD |
| Type | GPS: L1 C/A, L2C,
GLO: L1OF, L2OF,
GAL: E1B/C
BDS: B1I, B2I
184 Channel Parallel-tracking
receiver |
| Frequency | 1598 Mhz |
| Sensitivity (Acquisition) | -148 dBm |
| Sensitivity (Tracking) | -167 dBm |
| Design | 1U rack-mount bracket designed
for 19 Inch Cabinets
Fabricated Heatsinks
IP40 (Ingress Protection Rating) |
| ENVIRONMENT | |
| Storage Temperature | -40 to +85 °C |
| Operating Temperature | -10 to+55 °C |
| Humidity | 0 – 95% RH, non-condensing |
| Power Drain | 60W max |
| Power Supplies | 1x or 2x Power Supplies High Voltage - AC/DC 120-240 VDC
100-240 VAC
Low Voltage - DC
40-110 VDC
|
| Ingress Protection | IP40 |
| Configuration Software | |
| Platform | HTTPS/SSL Browser-based configuration |
| MECHANICAL SPECIFICATION | |
| Dimensions | 1U(H) x 485(W) x 185(D) mm 2U/3U Size available based on output requirements |
| Mounting | 19” Rack |
| Weight | 2 KG [For 1U] |
| Oscillator Options | |
| Rubidium | TBC* |
| VCTCXO | TBC* |
| OCXO | TBC* |
| INPUT | |
| GNSS Antenna inputs | L1Band GNSS, BNC [F] |
| External 1PPS | TTL, BNC [F]* |
| External IRIG-B | TTL/AM, BNC [F]* |
| External 10Mhz | 0 to 13dBm, BNC [F]* |
| Impedance | 50 Ω Sine Wave |
| Input | DC IRIG-B Input (BNC) |
| Antenna Input | BNC 5V GNSS Input |
| Configuration | Web server Interface and Sertel Time Management Suite for complete accessibility and configurability of server.
SNMP for remote management Keypad for local configuration L1Band GNSS, BNC [F] |
| Ethernet Connections | RJ45 1GbE/Fast Ethernet
SFP 1GbE`/Fast Ethernet |
| Alarm Relay | 3-Pin Form-C NO/NC alarm relay |
| OUTPUT | |
| 1PPS | TTL, 50 Ω Impedance, BNC [F] |
| PTP[GM] | RJ45 Copper |
| PRP | Supports PRP without external RED BOX* |
| NTP/SNTP | RJ45 Copper |
| IRIG-B | AM [B125], BNC [F] |
| Fiber Output | ST Fibre 62.5/125 µm, ʎ 820 nm |
| Programmable Output | TTL or Frequency Output (1.544, 2.048, 10MHz, Sine or Square) (BNC)
TTL or AM IRIG-B Output (BNC)
TTL Input/Output (BNC)
ST Fiber (62.5/125 µm) multimode
HV MOSFET 300V 1A (2-pin)
|
| CLOCK ACCURACY TO UTC | |
| 1 PPS | < 100 ns |
| PTP Time Stamp | < 100 ns |
| NTP Timestamp | < 50 μs |
| NETWORK TIME SERVER OPTION | |
| IEEE 1588v2 (PTP) | P2P/E2E delay
1-Step/2-Step delay
C37.238:2011 Power Profile
C37.238:2017 Power Profile
ITU G.8265.1 Telecom Profile
ITU G.8275.1 Telecom Profile
IEEE 61850-9-3 Power Utility Profile |
| NTP/SNTP | Stratum 1 NTP & SNTP Time server
Multicast & Broadcast capability |
| SNMP | V1, V2C & V3 support can be
independently enabled
Configurable V1, V2C community
names & security groups
Fully configurable via SNMP; |
| Protocols supported | ARP, UDP, ICMP, DHCP,SNMP, HTTPS, IPV4 |
| PRP | IEC 62439-3 (2016)
Fast failover slave
Supports up to two PRP pairs
PTP (IEEE 1588v2) Default & Power Profiles |
| Security | User-Defined Access Control Lists (ACL)
|
| Notifications | NMP trap generation V1, V2C & V3
SNMPv3 traps can be authenticated & privatised via
USM
Syslog (RFC-3164 & 5424 verities) |
| TEST AND STANDARDS | |
| Dry Heat Test | IEC 60068-2-2 |
| Cold Test | IEC 60068-2-1 |
| Damp Heat (Steady State) Test | IEC 60068-2-3 |
| Sinusoidal Vibration Test | IEC 60068-2-6 |
| Dielectric Strength Test | IEC 60255-5-0 |
| Pulse Magnetic Field Test | IEC 61000-4-9,2016 |
| Radiated RF Power Disturbance | CISPR 14-1,2009 |
Voltage Fluctuation and Flicker Emission Test
| IEC 61000-3-3,2013 |
Harmonics, Inter Harmonics and Low
Frequency Immunity Test | IEC 61000-4-13,2002 |
| Electrostatic Discharge Immunity Test | IEC 61000-4-2,2008 |
| Radiated Susceptibility Test | IEC 61000-4-3,2010 |
| Electrical Fast Transient Immunity | IEC 61000-4-4,2012 |
| High Energy Surge Immunity Test | IEC 61000-4-5,2014 |
| Conducted RF Immunity Test | IEC 61000-4-6,2013 |
| Power Frequency Magnetic Field Test | IEC 61000-4-8,2009 |
Damped Oscillatory Sinusoidal Immunity
Test | IEC 61000-4-18,2011 |
| Voltage Dips and Interruption Immunity Test | IEC 61000-4-11 |
*Feature Available only on Specific requests and suitable price points
*Output ports & Input Ports are customizable based on the requirements
*Product development is continuous process, subject to change without prior notice | |