Sertel

AUDIO/VIDEO & BROADCAST INDUSTRY

Every camera, console and archive log in your facility deserves the same clock.

Sertel PreciseSync-GMC-300 GPS / GNSS PTP Time Synchronisation Server locks your cameras, routers, automation systems and media archives to a single UTC reference, so a multicam take in the gallery carries the same timestamp as the ingest record in your MAM database.

<15 ns

ACCURACY WITH GNSS SIGNAL LOCK

<100 ns

PTP TIMESTAMP ACCURACY TO UTC

5 GNSS

CONSTELLATIONS TRACKED, 184 CHANNELS

THE HIDDEN CLOCK INSIDE EVERY BROADCAST CHAIN

When frame timecodes diverge by milliseconds, production accountability drifts by hours.

Without a shared reference, every device in your facility is running its own clock.

A modern broadcast facility is not a single gallery with a vision mixer and a router. It is a tightly coupled mesh of IP switches, audio consoles, graphic engines, automation servers, caption systems and a media asset management database, and every one of those systems timestamps its own output with its own internal clock.

Without a single, disciplined reference, those internal clocks drift independently. A camera control unit records a take at 14:02:11.341. The playout automation system logs the same event at 14:02:11.106. The MAM ingest record uses a third value. By the time a compliance team or an editor needs to reconstruct a precise sequence of events, the log files tell three different stories about the same moment.

Sertel designed the PreciseSync-GMC-300 to remove that ambiguity entirely. A satellite-locked Stratum-1 PTP grandmaster, purpose-built for studio and IP media environments, feeds every protocol your facility already speaks, including PTP, IRIG-B and 1PPS, from a single rack unit. The result is one clock, one reference and one version of every event, across every system.

The problem

Four time-related failures that quietly cost broadcast facilities money.

These are the failure modes our field engineers encounter most often during commissioning audits at IP broadcast migrations, master control room upgrades and OB fleet integrations.

Multi-Camera Sync and Timecode Drift

When camera control units, replay servers and intercom matrices each free-run on their own internal clock, multicam timecodes diverge across an edit session. Editors spend hours realigning clips manually, and replay operators cannot lock cleanly to a reference signal for slow-motion work.

Mixed SDI and IP Timing References

Legacy SDI racks still rely on a dedicated sync pulse from a house reference generator. Newer IP routers, audio consoles and automation systems run on PTP or NTP. Most facilities end up managing two parallel time systems, and any mismatch between them creates visible glitches or log inconsistencies during production handovers.

Regulatory and As-Run Timestamp Gaps

Broadcast regulators and rights management systems require sub-second precision in as-run logs, closed caption files and ad insertion records. When the playout server and the automation system are not sharing a common UTC reference, even a small drift generates discrepancies that require manual review before regulatory submission.

Air-Gapped Production and Playout Networks

Pulling time from public NTP pools is incompatible with the network segmentation that playout and production LANs are built around. Security policies for on-air systems require an on-premises Stratum-1 source that engineers can fully control, audit and restore without any dependency on an external internet connection.

The Sertel solution

PreciseSync-GMC-300: every protocol your broadcast facility needs, in one grandmaster.

The PreciseSync-GMC-300 family was engineered for facilities where legacy SDI timing and modern IP media infrastructure have to coexist on the same rack. Connect the antenna, assign an IP address, and every production system on the network locks to UTC in minutes.

Multi-GNSS Receiver, 5 Constellations

Tracks GPS, GLONASS, Galileo, BeiDou and NavIC-IRNSS in parallel across 184 channels. Maintains a stable lock even from a rooftop shared with satellite uplink dishes in RF-dense broadcast environments.

PTP IEEE 1588v2 Grandmaster

Operates as a Stratum-1 PTP grandmaster with P2P and E2E delay measurement and 1-step or 2-step mechanisms. Supports multiple PTP profiles for broad compatibility with IP routers, consoles and video infrastructure from any manufacturer.

IRIG-B and Legacy Pulse Outputs

Distributes AM and TTL IRIG-B alongside differential pulse, serial and DCF77 outputs to keep legacy SDI equipment, master control clocks and studio wall displays synchronised while the rest of the facility migrates to IP.

OCXO Holdover Stability

A high-precision oven-controlled oscillator maintains microsecond-level timing accuracy during temporary GNSS outages, so on-air timing stays intact through antenna servicing, rooftop maintenance or brief satellite signal loss.

Three Form Factors for Any Installation

Available as a compact 1U rack unit (GMC-300), a fully redundant 3U system with dual GPS, dual master clock and dual power supply (GMC-300-R), or a DIN Rail-mountable unit for OB vehicle panels and space-constrained technical rooms (GMC-300-D).

SNMP Management and Alarm Monitoring

Dual redundant power, SNMP v1/v2c/v3 traps, syslog notifications and user-defined access control lists keep the grandmaster visible and auditable in any NOC or master control room, with hot-standby pairing available for N+1 deployments.

A single, auditable time domain for OT and IT.

  • •Same timestamps across studio, playout, MAM, CCTV and access control systems
  • •Sub-100 nanosecond PTP grandmaster reference for IP media networks and audio-over-IP workflows
  • •On-premises Stratum-1 source with no public NTP dependency and no firewall exceptions
  • •Hot-standby pairing for N+1 redundancy in mission-critical master control rooms
  • •SNMP traps, syslog and dashboard alerts on every grandmaster health event

Applications

Deployed across every corner of the broadcast and AV chain.

Broadcast Studios and IP Galleries

Acts as a PTP grandmaster for IP routers, vision mixers, audio consoles and graphic engines sharing a single production network, so every device in the gallery operates from the same UTC reference.

Outside Broadcast Vehicles

The DIN Rail variant (GMC-300-D) fits cleanly into an OB van technical rack, distributing IRIG-B and PTP to camera control units, replay servers and intercom matrices both within the vehicle and across the fibre link to the studio.

Master Control Rooms and Playout Centres

Keeps automation systems, traffic logs and as-run records on a shared UTC reference, so playout timestamps reconcile cleanly with caption files, ad insertion logs and rights management submissions every time.

Media Asset Management and Archives

Timestamps ingest, transcode and archive events consistently so a media file carries the same creation time in the MAM database, the nearline store and the caption record from the moment of capture.

Satellite Uplink and Transmission Sites

Provides a GNSS-locked reference at uplink and transmitter sites where internet-based NTP is unavailable or restricted by security policy, keeping transmission timing aligned with studio operations.

Multi-Site Networks and Affiliate Feeds

Keeps regional studios, contribution links and disaster recovery sites on a common UTC reference, so feed handovers are seamless and shared archive timestamps are consistent regardless of which site originated the content.

From our commissioning logs

What we learned deploying PreciseSync-GMC-300 at a multi-studio IP broadcast migration.

During a multi-studio IP migration at a regional broadcaster, the commissioning team discovered the core problem within the very first multicam rehearsal. The camera control units, the replay server and the automation log each reported a slightly different timestamp for the same programme event, with a 340 ms spread between the earliest and latest recorded value.

We replaced the existing free-running NTP source with a single PreciseSync-GMC-300 grandmaster on the production LAN, distributed IRIG-B to the remaining SDI-based equipment through fibre converters, and enabled PTP for the IP-native gear. Within 45 minutes, every device on the network was locked to UTC to within 100 nanoseconds.

The next scheduled live programme produced a clean, time-aligned event log across every system involved. The as-run record, the caption file and the MAM ingest log all carried consistent timestamps for the same event. That is the practical value of a properly disciplined grandmaster: decisions made on one consistent set of facts, not on log files that disagree with each other.

FAQ

Questions broadcast engineers ask us most.

Bring every camera, console and feed under one clock reference.

Talk to a Sertel field engineer about specifying the PreciseSync-GMC-300 family for your studio, OB fleet or broadcast network. We ship globally, configure on-site and back every deployment with full lifecycle support.

enquiry@sertelelectronics.com+91 98400 63003