Redundant Stratum 1 GNSS Time Server

GPS / GNSS PTP Time Server: PreciseSync-GMC-300-R

The PreciseSync-GMC-300-R is a redundant, multi-constellation GPS/GNSS time server built to keep substations, data networks and industrial control systems on a single, traceable time base. Every critical stage, from GNSS reception to the grand master clock, comparator and power supply, is duplicated, so synchronisation continues without interruption even if one path fails. It distributes IEEE 1588v2 PTP, NTP, IRIG-B and 1PPS signals at Stratum 1 accuracy to protection relays, RTUs, PLCs and industrial networks.

15 ns GNSS lock accuracy at Stratum 1
Full redundancy across GNSS receiver, master clock, comparator and power supply
OCXO standard, with a Rubidium holdover option for extended signal-loss protection
Compact 19 inch rack mount, 2U or 3U depending on output configuration

Request a Quote

Share your requirement and our sales engineering team will prepare a tailored quote.

PreciseSync - GMC - 300 - R

We respect your privacy. No spam, ever.

View Specifications
PreciseSync-GMC-300-R redundant PTP IEEE 1588 time server with dual LCD panels

Key Features

Built for Continuous, Traceable Time Across the Network

Time synchronisation only matters if it keeps working when something goes wrong. The PreciseSync-GMC-300-R is engineered around that principle, pairing full hardware redundancy with wide protocol support so every connected device, from a protection relay to a data centre switch, shares the same accurate time reference.

Multi-Constellation GNSS Tracking

Tracks GPS L1 C/A and L2C, GLONASS L1OF and L2OF, Galileo E1B/C and BeiDou B1I and B2I signals, with NavIC/IRNSS support, through a 184 channel parallel tracking receiver. Acquisition sensitivity of minus 148 dBm and tracking sensitivity of minus 167 dBm keep the receiver locked even where satellite visibility is limited.

15 ns GNSS Lock Accuracy

Delivers 15 ns GNSS lock accuracy with a PTP timestamp accuracy of under 100 ns, meeting the precision that protection relays, phasor measurement units and SCADA systems need for correct event sequencing and fault recording.

Stratum 1 NTP and PTP Distribution

Generates Stratum 1 time directly from the GNSS reference and distributes it as IEEE 1588v2 PTP, in both 1 step and 2 step, P2P and E2E modes, alongside NTP, so IT and OT networks can run from the same clock without a secondary reference server.

IRIG-B, 1PPS and Fiber Outputs

Supports IRIG-B in AM and TTL form, DCF77, 1PPS, PPM and PPH pulse outputs, differential serial outputs and ST fiber distribution at 820 nm, covering legacy protection equipment and modern fiber-fed substations from one chassis.

Built and Tested for Harsh Environments

Rated for minus 10 to plus 55 degrees C operation and minus 40 to plus 85 degrees C storage, and qualified against IEC 60068, the IEC 61000-4 EMC immunity series and IEC 60255-5-0 dielectric strength standards for substation and industrial deployment.

Secure Web-Based Configuration

Configurable over HTTPS/SSL through the Sertel Time Management Suite or from the front panel keypad, with SNMP v1, v2c and v3 monitoring, user defined access control lists and Syslog notification for centralised oversight.

Live signal flow

How the PreciseSync-GMC-300-R Keeps a Network on Time

Accurate network time starts in orbit and ends at the device that needs it. The PreciseSync-GMC-300-R carries a signal through three stages, each backed by redundant hardware, before it reaches a single downstream port.

  1. 01Receive

    The T-GPA-014-S15 helical GNSS antenna acquires signals from GPS, GLONASS, Galileo, BeiDou and NavIC/IRNSS constellations across a 24 channel parallel front end, feeding a dual, redundant GNSS receiver pair so reception continues even if one receiver path is lost.

  2. 02Discipline

    A high-stability oscillator, OCXO as standard or Rubidium for extended holdover, disciplines the incoming GNSS signal to UTC. If satellite signal is lost, the Rubidium option maintains 1 microsecond accuracy over a 24 hour holdover period, keeping downstream systems synchronised through short outages.

  3. 03Distribute

    The disciplined time base is distributed as Stratum 1 NTP and IEEE 1588v2 PTP over dual Gigabit Ethernet, plus IRIG-B, 1PPS and fiber outputs, so every connected relay, server and controller draws from the same reference at the same time.

PreciseSync - GMC - 300 - R

Multi-GNSS Grandmaster

Local Time

--:--:--.---

Now syncing → Power Substation

  • Power Substation

    IEC 61850-9-3 grid sync

    Syncing
  • Data Center

    Stratum-1 NTP for servers

  • Telecom / 5G

    PTP backhaul timing

  • Defense

    Hardened secure time

  • Broadcast

    Frame-accurate sync

  • Railways & Metros

    Signaling & SCADA

  • Finance

    MiFID II timestamping

  • Automation

    C&I process control

<15 nsGNSS lock accuracy
<100 nsPTP timestamp accuracy
1 µs / 24 hoursRubidium holdover drift

Applications

Where PreciseSync-GMC-300-R Is Deployed

Any network that depends on a shared, traceable time reference can run on the PreciseSync-GMC-300-R, including:

Technical Specifications

Full electrical, mechanical and protocol specifications for the PreciseSync-GMC-300-R.

GPS Antenna, Model T-GPA-014-S15

ParameterSpecification
Receiving FrequencyL1: 1575.42 MHz | L2: 1227 MHz | L5: 1176.45 MHz (1176 MHz on request)
Tracking CodeL-Band C/A code
Number of Channels24 channels, parallel
Antenna TypeHelical, axial ratio under 4 dB
Supply Voltage+5 V DC (internal)
Gain / Noise FigureOver 40 dB / under 1.5 dB
Operating Temperature-40 degrees C to +85 degrees C
Connector / MountingBNC; fixed roof mount, IP67
DimensionsDiameter 93 mm, height 133 mm

GPS Receiver

ParameterSpecification
ModelPreciseSync-GMC-300-R
ConstellationsGPS L1 C/A and L2C, GLONASS L1OF and L2OF, Galileo E1B/C, BeiDou B1I and B2I, NavIC/IRNSS
Channels184 channel parallel tracking
Frequency BandL1, L2 and L5
Sensitivity (Acquisition / Tracking)-148 dBm / -167 dBm
InterfaceTTL (normal high)
Input ConnectorBNC female, twist-lock
Output RateOnce per second
DisplayTwo 4x20 LCD panels
ProtocolsNMEA, Sertel format, Serial String ASCII
Physical Design3U and 2U rack-mount bracket for 19 inch cabinet, fabricated heatsinks

Oscillator Options

ParameterSpecification
OCXOStandard; high-precision 10 PPB stability
RubidiumStandard-grade option; 0.1 PPB stability with 1 microsecond / 24 hour holdover
Disciplined OscillatorAvailable, confirm at order depending on output configuration
VCTCXOAvailable, confirm at order depending on output configuration

FAQ

Frequently Asked Questions

Ready to Deploy Precision Time Across Your Network?

Talk to a Sertel engineer for a tailored configuration, datasheet and pricing for the PreciseSync-GMC-300-R.

Request a Quote

Share your requirement and our sales engineering team will prepare a tailored quote.

PreciseSync - GMC - 300 - R

We respect your privacy. No spam, ever.

+91 98400 63003