Sertel

DATA CENTERS & IT NETWORKS INDUSTRY

One Nanosecond-Accurate Clock Reference for Every Server, Switch and Security Log in Your Infrastructure

PreciseSync-GMC-300 series locks every hypervisor host, core switch, firewall, storage controller and SIEM collector in your data center to a single stratum-1 UTC reference. Every log line, every distributed trace and every audit record draws from the same clock, so a fault in one part of the stack tells the same story as a security alert in another.

<100 ns

PTP GRANDMASTER ACCURACY TO UTC

<1 µs

NTP TIMESTAMP ACCURACY AT SERVER

5 GNSS

CONSTELLATIONS: GPS, GLONASS, GALILEO, BEIDOU, NAVIC

THE HIDDEN BACKBONE OF EVERY LOG FILE

When Your Infrastructure Drifts by Milliseconds, Every Investigation Drifts by Hours

A modern data center is not one monolithic system running one clock. It is hundreds of physical servers, virtual machines, bare-metal hypervisors, top-of-rack switches, load balancers, firewalls and storage arrays, each writing timestamps into logs and traces using its own internal sense of time.

Without a shared reference, those clocks drift quietly and independently. A firewall records an event at 14:02:11.341, the application server logs the same request at 14:02:11.794, and the SIEM correlates them as two separate incidents. When something goes wrong, the first hour of response time disappears into reconciling timestamps instead of acting on the problem.

Sertel designed the PreciseSync-GMC-300 series precisely for environments like this. A satellite-locked stratum-1 reference feeds PTP IEEE 1588v2, IRIG-B, SNMP monitoring and syslog, the protocols your infrastructure already understands, from a single rack appliance or DIN-rail unit. Connect the antenna, assign an IP, and the entire network has a common, auditable time domain within minutes.

The problem

Four Time-Related Failures That Quietly Cost Data Center Teams Hours Every Week

These are the failure patterns Sertel engineers encounter most frequently when auditing enterprise data centers, financial trading infrastructure and co-location facilities across India and the Middle East.

Broken SIEM Log Correlation Across the Stack

When firewalls, servers and application containers each keep a slightly different clock, a single security event appears as three disconnected log entries. Investigations stall while analysts manually re-sequence events instead of responding. Root-cause timelines that should take minutes can take entire shifts.

Authentication Failures Caused by Clock Skew

Active Directory rejects Kerberos tickets once a client clock drifts more than five minutes from the domain controller. Hypervisor guests, containerised workloads and newly provisioned virtual machines are especially prone to drift, producing hard-to-reproduce login failures that look like application bugs but are actually clock problems.

Compliance Timestamp Gaps in Audit Evidence

Frameworks including ISO/IEC 27001, PCI DSS and MiFID II RTS 25 require event and transaction records to carry traceable, UTC-aligned timestamps. Auditors reject evidence from systems whose clock source and accuracy cannot be demonstrated, turning a straightforward compliance review into a significant remediation project.

Security Exposure From Public NTP Dependency

Pointing production servers at internet NTP pools means opening outbound paths through a security-segmented network and trusting a time source nobody on the security team controls, audits or can isolate during an incident. It is a common finding in enterprise penetration tests and ISO audits across the region.

The Sertel solution

PreciseSync-GMC-300 Series: Every Protocol Your Stack Needs, in One Form Factor Your Rack Already Has Room For

The GMC-300 series was designed for exactly the challenge a data center presents: a mix of legacy IRIG-B-based equipment, modern PTP-aware switching fabric and a SIEM platform that all need to trust the same clock. Choose the 1U rack unit, the fully-redundant 3U enterprise unit, or the compact DIN-rail variant, and your entire OT and IT network operates on one auditable time domain.

184-Channel Multi-GNSS Receiver

Tracks GPS, GLONASS, Galileo, BeiDou and NavIC across L1, L2 and L5 bands simultaneously. A 184-channel parallel-tracking architecture means fast satellite acquisition and a resilient fix even through antenna cable runs well over 100 metres from the roof to the server room floor.

PTP IEEE 1588v2 Grandmaster

Delivers sub-100-nanosecond PTP timestamps with full support for C37.238 Power Profile, ITU-T G.8265.1 and G.8275.1 telecom profiles, and both one-step and two-step delay mechanisms. Works with P2P and E2E delay measurement to match whatever PTP profile your switching fabric already runs.

IRIG-B AM and TTL Outputs

AM IRIG-B (B125) at 50 ohm impedance and TTL PWM IRIG-B outputs serve legacy protection relays, oscillography recorders and older IEDs that expect a coaxial time reference, so no existing equipment needs to be upgraded when you introduce a GPS reference clock.

SNMP v1/v2c/v3 and Syslog Monitoring

Independently configurable SNMP versions, authenticated SNMPv3 traps, and RFC-3164 and RFC-5424 syslog output feed straight into existing NOC dashboards and SIEM platforms, so GNSS lock status, holdover events and alarm relay changes appear alongside every other piece of infrastructure telemetry.

OCXO Holdover Stability

A high-precision, oven-controlled crystal oscillator holds 10 PPB frequency stability during a GNSS outage, antenna fault or planned maintenance window. NTP and PTP outputs remain stable throughout the holdover period rather than drifting with the loss of signal, keeping the entire network on schedule.

Full Redundancy Option (GMC-300-R)

The R variant builds redundancy at every critical system level: dual GPS receivers, dual master clocks, a comparator unit and dual power supplies. For mission-critical co-location, trading infrastructure and financial settlement networks where even a momentary timing gap is unacceptable, this is the specification to deploy.

A Single, Secure Time Domain for Every System on Your Network

  • •Same UTC timestamp across servers, switches, firewalls, hypervisors and SIEM log collectors
  • •Sub-100-nanosecond PTP grandmaster for distributed tracing, financial order matching and service mesh correlation
  • •On-premises stratum-1 source, no public NTP pools, no outbound firewall exposure to the internet
  • •Dual power supply and PRP pairing for N+1 availability on the production management network
  • •SNMP traps, syslog and dashboard alerts on every GNSS lock, holdover or alarm relay event

Product range

Three PreciseSync Models. One for Every Data Center Footprint.

Whether you are fitting a compact primary time server into a space-constrained rack, deploying a fully-redundant grandmaster for a mission-critical production floor, or mounting a panel-level PTP source inside an edge cabinet, the GMC-300 series covers the installation.

FeaturePreciseSync-GMC-300 · 1U Rack CompactPreciseSync-GMC-300-R · Redundant 3UPreciseSync-GMC-300-D · DIN Rail
Form Factor1U 19" Rack3U / 2U 19" RackDIN Rail
Timing Accuracy15 ns with GNSS lock15 ns with GNSS lock15 ns with GNSS lock
PTP Timestamp< 100 ns< 100 ns< 100 ns
GNSS ConstellationsGPS, GLONASS, Galileo, BeiDou, NavICGPS, GLONASS, Galileo, BeiDou, NavICGPS, GLONASS, Galileo, BeiDou, NavIC, L5
Channels184-channel parallel184-channel parallel184-channel receiver, 24-channel antenna
OscillatorOCXO 10 PPBOCXO 10 PPBOCXO 10 PPB
RedundancySingleFull (GPS, clock, PSU, comparator)Single
PTP IEEE 1588v2YesYesYes
IRIG-B OutputAM/TTL (BNC)AM/TTLAM output
Power Supply90-260 V AC/DC, dual option2x redundant 90-260 V AC/DC90-260 V AC/DC, dual supply A and B
ManagementHTTPS/SSL + Sertel TMS suiteHTTPS/SSL + Sertel TMS suiteHTTPS/SSL + Sertel TMS suite
Best ForSpace-efficient single-unit data centersMission-critical, zero-downtime networksPanel & cabinet edge installations

All models include the Sertel T-GPA-014-S15 active GNSS antenna kit with cable, lightning arrestor and mounting bracket.

Applications

Deployed Across Every Layer of the Modern IT and Data Center Stack

Hyperscale and Co-location Data Centers

Provides a single audit-ready time domain for shared facilities where multiple tenants, billing systems and SLA reports all depend on the same trusted UTC clock. Supports both PTP for new switching fabric and NTP for legacy server pools from one appliance.

Enterprise IT and Active Directory Networks

Keeps domain controllers, file servers and endpoint images inside the Kerberos five-minute clock-skew tolerance, eliminating a quiet but recurring source of authentication failures. A single PreciseSync GMC-300 on the management LAN is usually sufficient for a full campus network.

Financial Trading and Exchange Co-location

Supplies the sub-100-nanosecond PTP timestamps that order matching engines, market data feeds, trade surveillance systems and post-trade reporting platforms need to meet MiFID II RTS 25 and SEBI timestamp accuracy requirements.

Cloud, Virtualisation and Container Platforms

Aligns hypervisor hosts, Kubernetes nodes and service mesh sidecars to the same UTC reference so distributed traces and inter-service request logs reconstruct cleanly across dozens of microservices, removing the guesswork from latency debugging and SLO reporting.

Security Operations and SIEM Platforms

Gives the SIEM a single trusted time source to correlate firewall, endpoint and application logs during a security incident or a compliance review, instead of spending the first hour of response time reconciling timestamps from five different systems.

Disaster Recovery and Multi-Site Replication

Synchronises primary and DR sites to the same UTC reference so replication logs, failover event records and recovery point timestamps stay consistent across locations, making planned and unplanned failover testing clean and auditable.

From our commissioning logs

What We Learned Deploying PreciseSync-GMC-300-R at a Financial Services Co-location in Chennai

During a compliance audit at a Tier III co-location facility serving a cluster of banking and broking clients, the security team found that a single suspicious-access investigation had taken three engineers most of a working day. The core switch, the identity server and the application tier each logged the same event with clocks that disagreed by up to four minutes. The timeline was genuinely ambiguous; nobody could agree on the sequence of events with confidence.

The facility management team replaced a collection of client-side internet NTP configurations with a pair of PreciseSync-GMC-300-R units deployed in hot-standby configuration on the management network. IRIG-B was distributed to the older security appliances via fibre converters, and PTP IEEE 1588v2 was enabled for the newer switching fabric and virtualisation hosts. Within forty-five minutes, every device on the audited network segment was reading time within 100 nanoseconds of UTC.

The next access review, conducted three weeks later, took just under ninety minutes from first query to final report sign-off. Every log entry, from every system, told the same story in the same sequence. The practical value of a disciplined, shared clock reference is not a theoretical security improvement. It is hours of incident response time returned to the team every time something goes wrong.

Relevant products

Sertel Products for Data Centers and IT

PreciseSync-GMC-300 1U rack mount GPS GNSS PTP time server with front panel LCD

Stratum-1 GNSS Time Server

PreciseSync - GMC - 300

A compact 19 inch rack PTP time server with OCXO holdover and 15 ns timing accuracy under GNSS lock. One unit feeds PTP Ethernet, IRIG-B, 1PPS and any number of slave clocks.

Know more
PreciseSync-GMC-300-R redundant PTP IEEE 1588 time server with dual LCD panels

Redundant Stratum 1 GNSS Time Server

PreciseSync - GMC - 300 - R

Redundant GNSS receivers, master clocks, comparator and dual power supplies in a 2U or 3U Eurocard chassis. Built for substations and control rooms where time must never stop.

Know more
PreciseSync-GMC-300-D DIN rail GPS PTP time server for substation control panels

Stratum-1 PTP Time Server, DIN Rail

PreciseSync - GMC - 300 - D

A panel-mounted PTP time server that fits inside control cabinets without rack space. Delivers IRIG-B (AM) and PTP Ethernet from a multi-constellation GNSS receiver with OCXO holdover.

Know more
Sertel T-SL-300-100-6DN NTP time display with 100 mm red LED digits

Digital Display

NTP Time Display 100mm (T-SL-300-100-6DN)

A six-digit wall clock that pulls time straight from your NTP server over the existing Ethernet network. The everyday choice for offices, control rooms and production halls that already run a time server.

Know more
Sertel T-SL-DD-300-100-6DN NTP date display with 100 mm red LED digits

Digital Display

NTP Date Display 100mm (T-SL-DD-300-100-6DN)

Shows the current date in large LED digits, synchronised to the same NTP source as your clocks. Pair it with a time display at shift boards, gate houses and reception areas so logs and records never disagree.

Know more
Sertel T-SL-300-100-3DN NTP day of week display with red LED characters

Digital Display

NTP Day Display 100mm (T-SL-300-100-3DN)

A compact three-character display that names the day of the week, driven by NTP. Useful on shop floors and in maintenance bays where weekly schedules and rotating shifts decide who works where.

Know more
Sertel T-SL-300-100-ADN alphanumeric LED display showing plant parameters and master clock time

Digital Display

NTP Alpha Numeric Display 100mm (T-SL-300-100-ADN)

A 28-character, multi-row LED board that combines time and date with live plant values such as frequency, MW output or ambient temperature. Reads data over Ethernet, OPC or 4-20 mA and supports scrolling and flashing messages.

Know more
Sertel T-SL-300-150-6DN large format 150 mm red LED time display for wall mounting

Digital Display

NTP Time Display 150mm (T-SL-300-150-6DN)

Our largest standard time display, built for turbine halls, warehouses and assembly floors where staff read the clock from a distance. Accepts NTP, PTP, IRIG-B, RS-232, RS-485 or differential pulse input in a wall-mount housing.

Know more
Sertel T-SL-300-014-6DN compact NTP time display with 14 mm LED digits for panel mounting

Digital Display

NTP Time Display 14mm (T-SL-300-014-6DN)

A small-character NTP clock sized for panel fronts, server racks and operator consoles. It brings the same synchronised time to close-range viewing points where a wall display would be oversized.

Know more
Sertel T-SL-300-100-6D IRIG-B slave clock display with 100 mm red LED digits

Digital Display

IRIG - B Time Display 100mm (T-SL-300-100-6D)

A slave clock for sites that distribute time from a master clock rather than over the LAN. IRIG-B or differential pulse input on a multi-drop bus drives up to 300 displays within a 1 km radius, and one failed unit never stops the rest.

Know more
Sertel GNSS receiver (MF-GNSS-300)

MULTI-FREQUENCY · MULTI-CONSTELLATION GNSS

GNSS receiver (MF-GNSS-300)

Multi-constellation GNSS reception for positioning, navigation and timing, with interfaces and configurations matched to the application.

Know more
Sertel T-WT-300 industrial LoRa wireless transceiver with integrated data logger, front panel view

LoRa RF Industrial Transceiver

Wireless Transceiver

An industrial LoRa RF gateway linking remote monitoring points to a Modbus-ready network, with local data logging.

Know more

FAQ

Questions Data Center and IT Teams Ask Us Most

Bring Every Clock in Your Infrastructure Under One Reference

Talk to a Sertel field engineer about specifying the PreciseSync-GMC-300 series for your data center, campus network or co-location environment. We ship across India and the Middle East, configure on-site, and support every deployment through its full operational life.

enquiry@sertelelectronics.com+91 98400 63003