POWER GENERATION, TRANSMISSION & DISTRIBUTION INDUSTRY

One Time Reference for Every Node Across Your Power Network

Sertel's PreciseSync family covers both timing protocols your power network needs. The SMC-300 series delivers Stratum 1 NTP and SNTP synchronisation to SCADA hosts, DCS controllers and protection relays that speak network time. The GMC-300 series acts as a PTP IEEE 1588v2 grandmaster for IEC 61850 substations and process bus IEDs where sub-microsecond precision is mandatory. One product family, every protocol, three form factors to fit whatever your site demands.

<15 ns

TIMING ACCURACY WITH GNSS SIGNAL LOCK

<100 ns

PTP, IRIG-B AND 1PPS ACCURACY TO UTC

5 Constellations

GPS · GLONASS · GALILEO · BEIDOU · NAVIC

THE HIDDEN BACKBONE OF A STABLE GRID

When Your NTP Network and Your PTP Substations Disagree on the Time, Every Event Record Becomes a Debate

A modern power utility operates devices across three distinct time protocol environments simultaneously. Its SCADA servers and DCS control rooms rely on NTP. Its IEC 61850 substations and process bus merging units demand PTP IEEE 1588v2. And its legacy relays, disturbance recorders and RTUs expect IRIG-B. Most organisations try to address these three requirements with three different time sources, and the result is three subtly different clocks.

When a protection relay trips, the relay, the substation IED and the control room SCADA can each log the event with a timestamp from a different reference. Engineers then spend days reconciling logs that were never aligned to begin with. The investigation stalls. Root cause becomes conjecture. And the next incident finds the same clocks still drifting.

Sertel designed the PreciseSync family to remove that ambiguity. The SMC-300 NTP servers and GMC-300 PTP grandmasters both derive from the same GNSS satellite constellation and share the same UTC reference. When you deploy them together, every NTP client and every IEC 61850 IED timestamps from the same second, to the nanosecond. One family covers both protocols, so the clock drift debate disappears entirely.

The problem

Four Timing Failures That Quietly Cost Power Utilities Money

These are the failure modes our field engineers encounter most often during commissioning audits at thermal, hydro and renewable plants and substations across India and the Middle East.

Post-Event Records That Cannot Be Trusted

When a protection relay, a substation IED and a control room SCADA each run on a different time reference, the same fault produces three different timestamps. Post-event analysis (PEA) reports become internally inconsistent. Root-cause meetings end in clock-drift arguments rather than corrective action.

Protocol Mismatch Between Legacy and Digital Substations

Older substations use IRIG-B. New IEC 61850 process bus installations require PTP. Utilities caught between both generations often run parallel time systems, which multiplies maintenance overhead and leaves the two domains with no common reference.

Grid-Code and Regulatory Timestamp Compliance

CERC, NERC and ENTSO-E reporting mandates sub-second traceable timestamps for disturbance events. PMU data submissions, ABT energy accounting and renewable curtailment records are rejected when timestamps cannot be traced to a certified UTC source.

OT Networks That Cannot Pull Time from Public Infrastructure

IEC 62443 network segmentation rules prohibit pulling time from public NTP pools in air-gapped control networks. Utilities need an on-premises, auditable time source they control entirely, without opening firewall holes to the outside.

The Sertel solution

NTP and PTP Time Servers Purpose-Built for Power Utilities

The PreciseSync family gives utility engineers a single vendor source for both protocols, with three form factors that match every installation environment from control room racks to panel-mounted DIN rails.

PreciseSync-SMC-300 | Stratum 1 NTP / SNTP Server

A compact 1U 19" rack-mount NTP time server with 184-channel multi-GNSS reception, 30 ns accuracy with GNSS lock, OCXO holdover and IRIG-B outputs. Feeds NTP and SNTP with multicast and broadcast to an unlimited number of SCADA hosts, DCS controllers, RTUs and network clients. Managed via the Sertel Time Management Suite over HTTPS.

PreciseSync-GMC-300 | PTP IEEE 1588v2 Grandmaster

A compact 1U rack-mount PTP grandmaster supporting C37.238:2011 and C37.238:2017 Power Profiles, IEC 61850-9-3 Power Utility Profile and ITU telecom profiles. P2P and E2E delay measurement, 1-step and 2-step mechanisms, and PRP support for IEC 62439-3 high-availability ring topologies. Clocks process bus merging units and IEDs to within 100 nanoseconds of UTC.

SMC-300-R / GMC-300-R | Full-Redundancy Eurocard Variants

Designed for mission-critical sites that cannot tolerate downtime. Redundancy is built in at every level: dual GPS receivers, dual master clocks, a comparator unit that monitors both clocks and selects the better reference, and dual power supplies. Any single component can fail without interrupting time distribution to connected devices.

SMC-300-D / GMC-300-D | DIN Rail Variants

Compact DIN Rail-mounted NTP and PTP servers for panel installations where rack space is unavailable. A 184-channel multi-GNSS receiver with a 24-channel antenna tracks constellations including NavIC-IRNSS, with IPv4/IPv6 Ethernet, IRIG-B (AM) output and wide-range 90 to 260 V AC/DC power on dual supply inputs. Ideal for distribution substations and control panels with limited space.

OCXO Holdover Across All Variants

Every PreciseSync model is equipped with a high-precision, oven-controlled crystal oscillator. When satellite signal is lost due to antenna obstruction, maintenance or adverse conditions, the OCXO maintains microsecond-level timing accuracy throughout the holdover period. The Rubidium oscillator option delivers 0.1 PPB stability with 1 microsecond accuracy over 24 hours.

5-Constellation GNSS Including NavIC-IRNSS

The PreciseSync receiver tracks GPS, GLONASS, Galileo, BeiDou and NavIC-IRNSS signals across L1, L2 and L5 frequency bands with 184-channel parallel tracking. Support for India's own NavIC regional constellation provides an additional satellite layer for installations in South Asia where NavIC visibility is highest, improving lock resilience in dense urban or obstructed substation yards.

A Single Auditable Time Domain for OT and IT

  • •Same UTC-traceable timestamp across NTP-fed SCADA, PTP-fed IEC 61850 IEDs, and IRIG-B-fed protection relays
  • •Sub-microsecond PTP grandmaster for IEC 61850-9-2 process bus substations, with C37.238 and IEC 61850-9-3 Power Profiles
  • •On-premises Stratum 1 source, no public NTP dependency, fully compatible with IEC 62443 OT network segmentation
  • •Hot-standby pairing for N+1 redundancy on the NTP and PTP servers, with full component redundancy on the R variants
  • •SNMP V1/V2c/V3 traps, syslog and user-defined ACL-based access control for audit-ready network monitoring

Applications

Deployed Across Every Tier of the Power Delivery Chain

Thermal and Gas Turbine Plants

The SMC-300 synchronises governor controls, vibration monitors, DCS and sequence-of-event recorders so every trip and load rejection reconstructs cleanly to the cycle. Where turbine control systems include IEC 61850 IEDs, the GMC-300 serves as the PTP grandmaster for the entire protection network.

Hydroelectric Stations

Provides NTP and PTP to unit-control panels and excitation systems across long penstock LAN runs. The DIN Rail D variant handles time distribution in compact control panels at remote turbine bays where rack-mount space is not available.

Solar PV Farms

The SMC-300 timestamps inverter telemetry, curtailment commands and grid-code compliance data. Where the site uses an IEC 61850 MMS data concentrator, the GMC-300 supplies the PTP reference to keep process data and event records aligned across hundreds of inverter controllers.

Wind Power Parks

Aligns turbine SCADA, WTG controllers, meteorological mast sensors and generation meters so production audits and curtailment records reconcile to the second. NavIC-IRNSS support on the D and base variants improves satellite lock in coastal and offshore-adjacent sites across India.

EHV Substations

The GMC-300 provides PTP IEEE 1588v2 to IEC 61850-9-2 merging units and IEDs on the process bus. The SMC-300 feeds NTP to the station HMI, historian and SCADA. Together they create one time domain across both the process bus and the station bus from a single Stratum 1 GNSS source.

Load Dispatch and SLDC Interfaces

Delivers regulator-grade NTP timestamps for tie-line metering, ABT reporting and frequency-response data submissions. Where the dispatch centre connects to IEC 61850-capable substations, the GMC-300 maintains the PTP grandmaster hierarchy for the entire WAMS or synchrophasor network.

From our commissioning logs

What We Learned Commissioning PreciseSync at a Mixed-Protocol Power Utility

At a 400 kV switching substation serving a mix of legacy electromechanical relays and a new IEC 61850 bay controller installation, the engineering team had deployed separate NTP and PTP references on two independent servers. The two sources drifted by up to 3 milliseconds during periods of cloud cover affecting the primary NTP server antenna. Disturbance records from the IEC 61850 IEDs and the legacy IRIG-B-fed relays could not be reconciled without manually correcting the timestamp offset on every event.

We replaced both servers with a single PreciseSync-GMC-300 for the IEC 61850 process bus and a PreciseSync-SMC-300 on the station NTP network, both fed by the same active GNSS antenna and deriving from the same UTC reference. Within two hours every IED, relay and SCADA client on site was within 100 nanoseconds of UTC. The manual timestamp correction step was eliminated from the PEA workflow.

The first protection event after commissioning produced a single, continuous, time-aligned sequence of records across both the IEC 61850 IEDs and the legacy relays. The investigation that would previously have taken three days closed in one shift. That is what a shared GNSS reference across both protocols delivers in practice.

Relevant products

Sertel Products for Power Utilities

PreciseSync-SMC-300 1U rack mount GPS / GNSS NTP time server

GPS / GNSS NTP TIME SERVER

PreciseSync - SMC - 300

A 1U 19 inch rack Stratum 1 server with 14 ns timing accuracy under GNSS lock and a front-panel LCD. It drives slave clocks and digital displays directly, alongside NTP, IRIG-B and DCF77 outputs.

Know more
PreciseSync-SMC-300-R redundant GPS time synchronisation server, 3U rack

GPS / GNSS NTP Time Server

PreciseSync - SMC - 300 - R

Duplicated GPS receivers, master clocks, comparator units and power supplies on Eurocard PCB construction. Built for substations and control systems that must keep time through a component failure.

Know more
PreciseSync-SMC-300-D DIN rail GPS / GNSS NTP time server

Stratum-1 GNSS Time Server

PreciseSync - SMC - 300 - D

A panel-mounted Stratum 1 server for control cabinets without rack space. It sends IRIG-B (AM) and NTP over Ethernet to SCADA, IEDs and protection relays from a single DIN rail unit.

Know more
PreciseSync-GMC-300 1U rack mount GPS GNSS PTP time server with front panel LCD

Stratum-1 GNSS Time Server

PreciseSync - GMC - 300

A compact 19 inch rack PTP time server with OCXO holdover and 15 ns timing accuracy under GNSS lock. One unit feeds PTP Ethernet, IRIG-B, 1PPS and any number of slave clocks.

Know more
PreciseSync-GMC-300-R redundant PTP IEEE 1588 time server with dual LCD panels

Redundant Stratum 1 GNSS Time Server

PreciseSync - GMC - 300 - R

Redundant GNSS receivers, master clocks, comparator and dual power supplies in a 2U or 3U Eurocard chassis. Built for substations and control rooms where time must never stop.

Know more
PreciseSync-GMC-300-D DIN rail GPS PTP time server for substation control panels

Stratum-1 PTP Time Server, DIN Rail

PreciseSync - GMC - 300 - D

A panel-mounted PTP time server that fits inside control cabinets without rack space. Delivers IRIG-B (AM) and PTP Ethernet from a multi-constellation GNSS receiver with OCXO holdover.

Know more
Sertel T-SL-300-100-6DN NTP time display with 100 mm red LED digits

Digital Display

NTP Time Display 100mm (T-SL-300-100-6DN)

A six-digit wall clock that pulls time straight from your NTP server over the existing Ethernet network. The everyday choice for offices, control rooms and production halls that already run a time server.

Know more
Sertel T-SL-DD-300-100-6DN NTP date display with 100 mm red LED digits

Digital Display

NTP Date Display 100mm (T-SL-DD-300-100-6DN)

Shows the current date in large LED digits, synchronised to the same NTP source as your clocks. Pair it with a time display at shift boards, gate houses and reception areas so logs and records never disagree.

Know more
Sertel T-SL-300-100-3DN NTP day of week display with red LED characters

Digital Display

NTP Day Display 100mm (T-SL-300-100-3DN)

A compact three-character display that names the day of the week, driven by NTP. Useful on shop floors and in maintenance bays where weekly schedules and rotating shifts decide who works where.

Know more
Sertel T-SL-300-100-ADN alphanumeric LED display showing plant parameters and master clock time

Digital Display

NTP Alpha Numeric Display 100mm (T-SL-300-100-ADN)

A 28-character, multi-row LED board that combines time and date with live plant values such as frequency, MW output or ambient temperature. Reads data over Ethernet, OPC or 4-20 mA and supports scrolling and flashing messages.

Know more
Sertel T-SL-300-150-6DN large format 150 mm red LED time display for wall mounting

Digital Display

NTP Time Display 150mm (T-SL-300-150-6DN)

Our largest standard time display, built for turbine halls, warehouses and assembly floors where staff read the clock from a distance. Accepts NTP, PTP, IRIG-B, RS-232, RS-485 or differential pulse input in a wall-mount housing.

Know more
Sertel T-SL-300-014-6DN compact NTP time display with 14 mm LED digits for panel mounting

Digital Display

NTP Time Display 14mm (T-SL-300-014-6DN)

A small-character NTP clock sized for panel fronts, server racks and operator consoles. It brings the same synchronised time to close-range viewing points where a wall display would be oversized.

Know more

FAQ

Questions Power Utility Engineers Ask Us Most

Specify the Right PreciseSync Model for Your Site

Talk to a Sertel field engineer about which PreciseSync variant suits your generation, transmission or distribution installation. We will help you select between NTP and PTP, standard rack and full-redundancy, and specify the right oscillator and output configuration for your protection philosophy and grid-code requirements. We ship across India and the Middle East, configure on-site and support every deployment through its operational life.